How to Order
How To Order Century-Line® Sleeves & Link-Seal® Modular Seals
1. Click here to access charts for type of pipe listed below.
SDR-35 Gravity Sewer Pipe Steel and Plastic Pipe with Same Outside Diameter
Ductile Iron Pipe (AWWA-C900, C905, PVC Water Pipe) Copper Tubing
Cast Iron Soil Pipe (Extra Heavy) Cast Iron Soil Pipe (Service Weight)
Electrical Metallic Tubing (EMT) Thin Wall Intermediate Metal Conduit (IMC)
Rigid (RSC), Aluminum (ASC), Galvanized (GSC), Non-Metallic Conduit (NRC)
2. Verify that your pipe O.D. matches the actual outside diameter shown on the chart.
3. Begin at column heading "Pipe Size - Nominal". Read across to the sizing section for your sleeve type
and/or wall opening. (In this case CS Model Non-Metallic Sleeve)
PIPE SIZE (Nom.) | ACTUAL O.D. (Inches) |
CS MODEL NON-METALLIC SLEEVE | WS MODEL STEEL SLEEVE |
CAST OR CORE BIT DRILLED HOLE |
4. Determine Link-Seal® modular seal model to be used.
See Link-Seal® Options
5. Under the CS MODEL NON-METALLIC SLEEVE Column,
choose a Link-Seal® modular seal size (from LINK-SEAL SIZE column),
add the Link-Seal® Modular Seal Model designation in place of (***)
(See Link-Seal Options) and indicate number of links required per seal
(from LINKS PER SEAL column).
Example:
LS-200-
C -4
|
Pipe Size (Nominal) | Actual O.D. (inches) |
CS Model Non-Metallic Sleeves |
Model Number |
Link-Seal Size |
Links Per Seal |
1/2" | .840 |
CS-2-* |
LS-200-*** | 4 |
* = Specify Length *** = Specify Link-Seal® Modular Seal Model Number
6. To order corresponding CS sleeves indicate model number (from MODEL NUMBER column)
and length of sleeve in inches (12"). Example:
CS-2 -12
7. To complete the order, use Link-Seal Product Number from above LS-200-C-4 with CS Sleeve Product Number
CS-2-12 followed by the number of same size penetrations.
Example: LS-200-C-4 with CS-2-12 - 10 Penetrations Note: Contact PSI (1-800-423-2410)
or your local distributor if your pipe sizing solution is not listed in the provided charts.
How To Order WS (Steel) Sleeves & Link-Seal® Modular Seals
1. Click here to access charts for type of pipe listed below. SDR-35 Gravity Sewer Pipe
Steel and Plastic Pipe with Same Outside Diameter Ductile Iron Pipe (AWWA-C900, C905, PVC Water Pipe)
Copper Tubing Cast Iron Soil Pipe (Extra Heavy) Cast Iron Soil Pipe (Service Weight)
Electrical Metallic Tubing (EMT) Thin Wall Intermediate Metal Conduit (IMC)
Rigid (RSC), Aluminum (ASC), Galvanized (GSC), Non-Metallic Conduit (NRC)
2. Verify that your pipe O.D. matches the actual outside diameter shown on the chart.
3. Begin at column heading "Pipe Size - Nominal". Read across to the sizing section for your sleeve type and/or wall opening.
(In this case WS Model Steel Sleeves) PIPE SIZE (Nom.) |
ACTUAL O.D. (Inches) | CS MODEL NON-METALLIC SLEEVE |
WS MODEL STEEL SLEEVE | CAST OR CORE BIT DRILLED HOLE |
4. Determine Link-Seal® modular seal model to be used. See Link-Seal® Options
5. Under the WS MODEL STEEL SLEEVE Column,
choose a Link-Seal® modular seal size (from LINK-SEAL SIZE column),
add the Link-Seal® Modular Seal Model designation in place of (***) (See Link-Seal Options)
and indicate number of links required per seal (from LINKS PER SEAL column).
Example: LS-275-
C -5
Pipe Size (Nominal) |
Actual O.D. (inches) |
WS MODEL STEEL SLEEVE | Model Number |
Link-Seal Size |
Links Per Seal | 1/2" | .840 |
WS-2-15-S-* |
LS-275-*** | 5 |
* = Specify Length *** = Specify Link-Seal® Modular Seal Model Number
6. To order corresponding WS Sleeves indicate model number
(from MODEL NUMBER column) and length of sleeve in inches (12"). Example:
WS-2-15-S -12
7. To complete the order, use Link-Seal Product Number from above LS-215-C-5 with WS Sleeve Product Number
WS-2-15-S-12 followed by the number of same size penetrations.
Example: LS-215-C-5 with WS-2-15-S-12 - 10 Penetrations
Note: Contact PSI (1-800-423-2410) or your local distributor if your pipe sizing solution is not listed in the provided charts.
How To Order Link-Seal® Modular Seals for Cast or Core Bit Drilled Holes
1. Click here to access charts for type of pipe listed below.
SDR-35 Gravity Sewer Pipe Steel and Plastic Pipe with Same Outside Diameter
Ductile Iron Pipe (AWWA-C900, C905, PVC Water Pipe) Copper Tubing
Cast Iron Soil Pipe (Extra Heavy) Cast Iron Soil Pipe (Service Weight)
Electrical Metallic Tubing (EMT) Thin Wall Intermediate Metal Conduit (IMC)
Rigid (RSC), Aluminum (ASC), Galvanized (GSC), Non-Metallic Conduit (NRC)
2. Verify that your pipe O.D. matches the actual outside diameter shown on the chart.
3. Begin at column heading "Pipe Size - Nominal". Read across to the sizing section for your sleeve type and/or wall opening.
(In this case Cast or Cored Bit Drilled Hole)
PIPE SIZE (Nom.) | ACTUAL O.D. (Inches) |
CS MODEL NON-METALLIC SLEEVE | WS MODEL STEEL SLEEVE |
CAST OR CORE BIT DRILLED HOLE |
4. Determine Link-Seal® modular seal model to be used. See Link-Seal® Options
5. Under the CAST OR CORED BIT DRILLED HOLE Column,
choose a Link-Seal® modular seal size (from LINK-SEAL SIZE column),
add the Link-Seal® Modular Seal Model designation in place of (***) (See Link-Seal Options)
and indicate number of links required per seal (from LINKS PER SEAL column).
Example:
LS-200-
C -
4
|
Pipe Size (Nominal) | Actual O.D. (inches) |
CAST OR CORE BIT DRILLED HOLE |
Hole I.D. Number |
Link-Seal Size |
Links Per Seal | 1/2" |
.840 |
2.000 | LS-200-*** |
4 |
*** = Specify Link-Seal® Modular Seal Model Number 6. Cut all penetrations (holes) at 2.000 I.D.
for designated pipe Type and Nominal Diameter. 7. To complete the order, use Link-Seal Product Number from above
LS-200-C-4 and add number of penetrations.
Example: LS-200-C-4 - 10 Penetrations
Note: Contact PSI (1-800-423-2410) or your local distributor if your pipe sizing solution is not listed in the provided charts.
How To Order Link-Seal® Modular Seals for use with Holes Molded with Cell-Cast® Disks
1. Click here to access charts for type of pipe listed below. SDR-35 Gravity Sewer Pipe
Steel and Plastic Pipe with Same Outside Diameter Ductile Iron Pipe (AWWA-C900, C905, PVC Water Pipe)
NOTE: Cell-Cast® Disks are used to form holes 30" in diameter and larger at any thickness.
You will find Cell-Cast® Disks on the lower portion of CS MODEL NON-METALLIC SLEEVE
Column where your carrier pipe size will require a molded hole of 30" I.D. and over. Cell-Cast® Disks are designated with the Model Number
CC rather than CS for Century-Line® Sleeves. 2. Verify that your pipe O.D. matches the actual outside diameter
shown on the chart. 3. Begin at column heading "Pipe Size - Nominal". Read across to the sizing section for your sleeve type and/or
wall opening. (In this case CS Model Non-Metallic Sleeve) |
PIPE SIZE (Nom.) | ACTUAL O.D. (Inches) | CS MODEL NON-METALLIC SLEEVE |
WS MODEL STEEL SLEEVE | CAST OR CORE BIT DRILLED HOLE |
4. Determine Link-Seal® modular seal model to be used. See Link-Seal®
Options 5. Under the CS MODEL NON-METALLIC SLEEVE Column,
choose a Link-Seal® modular seal size (from LINK-SEAL SIZE column),
add the Link-Seal® Modular Seal Model designation in place of (***) (See Link-Seal Options)
and indicate number of links required per seal (from LINKS PER SEAL column).
Example: LS-600-
C -
13
Note on the following chart that a Nominal Pipe I.D. of 18" designates a Model
CS (Century-Line® Sleeve) while a Nominal Pipe I.D. of 21 designates a Model
CC (Cell-Cast® Disk) for hole forming.
Pipe Size (Nominal) |
Actual O.D. (inches) |
CS MODEL NON-METALLIC SLEEVE |
Model Number |
Link-Seal Size |
Links Per Seal |
18 |
18.70 | CS-24-* |
LS-575-*** |
21 | 21 | 22.05 |
CC-30-** |
LS-600-*** | 13 |
** = See Cell Cast® *** = Specify Link-Seal® Modular Seal Model Number
6. Determine thickness of wall where Cell-Cast® Disks will be used to form a hole. 7. Cell-Cast® Disks are
available in two thicknesses (3" and 4"). You may therefore combine 3" and 4" thick Cell-Cast® Disks to match almost
any wall thickness. For example: To mold a hole in a 18" thick wall, one would use 3-4" Cell-Cast® Disks and 2-3"
Cell-Cast® Disks. 8. To complete the order, use Link-Seal Product Number from above LS-600-C-13 in
combination with your Cell-Cast® Disk requirements CC-30-(3)2 - (4)3 9. Include the number of
penetrations in your final order by using the following ordering code addition. Example: LS-600-C-13 with CC-30-(3)2-(4)3 - 3
Penetrations. Note: Contact PSI (1-800-423-2410) or your local distributor if your pipe sizing solution is not
listed in the provided charts.
|